Measuring range:0-50000LUX 0-5000FC
3 RANGE: x1,x10,x100
resolution: 1
Accuracy: ±5%n
HOLD
Band pass filter
Overload indication: 1
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 97x53x17mm
Weight (not including probe): 183g
2. Lux Meter
Range : Lux, 40, 400, 4,000, 40,000, 400,000
Foot candle : 40, 400, 4,000, 40,000.
Resolution : 0.01.
Basic accuracy : ±3% rdg + 5 digits.
Dimensions : 5.9” x 2.8” x 1.4
3. Solarimeter Kimo
Solar irrigation measuring range : 1 W/ m2 to 1300 W/ m2
Energetic exposure measuring range : 1 Wh/ m2 to 500 kWh/ m2
Frequency of the measure : 2 / s
Accuracy : 5% of measurement
Calculation frequency ( W/ m2) : 1 / min ( average on 60 seconds)
Storage capacity : 31 days, 44640 saved recording points
Fast datas download : 1000 values/ second
Detection : out of range and sensor default
Operating temperature : from -10° C to + 50° C
Storage temperature : from -10° C to + 55° C
Package dimensions : 58 x 120 x 33 mm
Autonomy : more than 72 hours in continuous mode
Unlimited with power supply adapter
Power supply : 3 LR3-AAA batteries
Electronic : Digital
E lectronic card : Varnish
Conformity : in accordance with RoHS directives
4. Gauss Meter
Gauss Meter
Range (ST Probe): Up to 30,000 Gauss /1G indicates polarity
Range/Resolution (HS Probe): 0 to799.99 Gauss / 0.01G indicates polarity
Accuracy (w/ probe) 16° to 29°C: 1% of DC reading / 3% AC +/- 10 Counts / 1% peak hold
Accuracy (w/ probe) -4° to 65°C: 2% of DC reading / 4% AC +/- 10 Counts / 2% peak hold
AC Frequency Range: 45-800 Hz; 3 dB limits are 11 to 1500 Hz.
Peak Hold Speed: 2 millisec pulse is 71%, 5+ millisec pulse is 100%±1%
Output Type: Analog DC Signal.
Output Magnitude (ST Probe): Below 20kG, output is 0.1mV/G. Above 20kG, it is 0.01 mV/G
Output Magnitude (HS Probe): 1mV/G
Meter Size: 138 x 91 x 41 mm
Weight: 7.5 Oz
Battery: 9 volt alkaline (~40 hour life with ST probe, ~ 20 with HS probe); ""Low Battery"" indicator
5. Survey Meter
Operating Range:
mR/hr - .001 (1µR) to 100 mR/hr
µSv/hr - .01 to 1000
CPM - 0 to 300,000
CPS - 0 to 5000
Total/ Timer - 1 to 9,999,000 counts
Accuracy (Referenced to Cs-137):
mR/hr ± 15% from 0 to 30 mR/hr, ± 20% from 30 to 50 mR/hr
CPM ± 15% : 0 to 100,000 cpm, ± 20% from 100,000 to 300,000 cpm
Timer: Can set 1-minute sampling periods from 1 to 10 minutes
10-minute sampling periods from 10 to 60 minutes
1-hour sampling periods from 1 to 24 hours
Count Light: Red LED flashes with each radiation event
Audio Indicator: Internally mounted beeper (can be switched off for silent operation)
Anti-Saturation: Meter will hold at full scale in fields as high as 100 times the maximum reading
Power Requirements: (1) 9-volt alkaline battery
Temperature Range: 14°F to 122°F (-10°C to +50°C)
Battery Life: Typically 200 hours at normal background radiation levels
Dimensions: 5.9"" h x 3.3"" w x 1.2"" d (15 x 8 x 3 cm)
Weight: 10.6 oz (300 grams) without battery.
6. Sling Psycrometer
Psychrometer Sling
Untuk mengukur kelembaban udara dengan menggunakan 2 buah thermometer air raksa.
Specifications:
Batas pengukuran thermometer: -15 hingga +40°C
Skala thermometer: 0,2°C
Ukuran peralatan: 260 x 180 x 20 mm
Berat: 0,2 kg
7. Thermohygrometer
Humidity :
Range, 10% to 95%
Resolution : 0.1%
Accuracy : ±3.5%
Infrared Temperature :
Range : -58°F to 932°F (-50°C to 500°C)
Resolution : 0.1°
Accuracy : ±2% or ±4°F (±2°C)
Air temperature :
Range : -4°F to 140°F (-20°C to 60°C)
Resolution : 0.1°
Accuracy : ±3°F/°C
Emissivity : 0.95
Field of view: 8:1
Dimensions: 5.9” x 2.95” x 1.57”.
8. Digital Psychrometer Kit
Specification Digital Psychrometer Kit
Range :
Humidity : 10% to 90% RH
Temperature (Internal) : -4°F to 122°F (-20°C to 50°C)
Temperature (External) : -4°F to 158°F (-20°C to 70°C)
Dew Point : -90.4°F to 122°F (-68.0°C to 49.9°C);
Wet Bulb : -6.9°F to 122°F (-21.6°C to 49.9°C).
Maximum Resolution
Humidity : 0.1% RH
Temperature (Internal and External) : 0.1°.
Basic Accuracy
Humidity : ±3% RH
Temperature (Internal and External) : ±1°F or ±0.6°C. Dimensions : 7” x 1.9” x 1”. Weight: 3.3 oz.
9. Model AWA 6291 Real Time Signal Analyzer
Frequency Response:10 Hz~20 kHz±0.2 dB, 1 Hz~23 kHz(±1.0 dB)
Frequency Weighting: A, C, F(Flat)
Time Weighting: F, S, and linear average
Measuring Upper Limit: 130 dB(A),(re. 20 μPa)
Self-generated Noise: <18 dB(A), 23 dB(C), 28 dB(Z)
Measurement of Peak C sound level: 50~143 dB
Linearity Range: 90dB
Sampling Frequency48 kHz
A/D bits: 24 bits
Integrating Time: Manual, 10s, 1min, 10min, 15min,20min, 1h, 4h, 8h, 24h
Anti-aliasing Filter: Cutoff frequency is 23.5 kHz and stopband attenuation is 100 dB
10. Noise Dosimeter
Items : ASV5910
Fulfils Standards : IEC61672 Class 2,IEC61252
Microphone : 1/4”Prepolarized Condenser Mic. including the preamplifier sensitivity about-50 dB
Channel : 2
Frequency Range : Parallel (simultaneous) A, C, Z
Time Weighting : Parallel (simultaneous) F, S, I, peak
Measurement Range of Sound Exposure : 0.01Pa2h~99.99Pa2h
Noise Dose Measurement Range : 0%~9999%
Frequency Range : 20Hz-12.5kHz
The Sound Pressure Level Measurement Range : 60-140dBA,65-140dBC,70-140dBZ(sensitivity: -50 dB ) ; 40-120dBA,45-120dBC,50-120dBZ( sensitivity: -30 dB )
Self-generated Noise : <30dBA
Peak C Sound Level Measuring Range : 80-143dB
Display : 128×64
Outputs : Mini USB interface, no need for driver, or the USB Flash disk
Integrating Function : YES
Measure Parameters : LXYp, LXeq,T, LXYmax, LXYmin, LN, SEL, Lex8h, LAVG, TWA, DOSE, SD, Lpeak
Note: X is A, C, Z; Y is F, S, I; N can be 1-99"
"Statistical Analysis Function : YES
Integral Time : 1s~24h
Data Storage : 2GB Flash RAM , maximum 8187 groups
Download to PC : YES
Recording Precision : 32kHz/16bit,16kHz/16bit,8kHz/8bit optional and 48kHz/16bit, 24kHz/16bit,12kHz/8bit ( user order)
Overrun Instructions : YES
Working Temperature : 0°C~40°C
Dimensions : 68(H)×48(W)×20(D)
Weight : 100g
11. Sound Level Meter
Display: 10mm (0.4″) LCD (Liquid Crystal Display)
Function: LP , Leq ,LN.
Frequency range : 31.5Hz - 8kHz
Measurement range : LP:30 - 130dB (A) ; 35 - 130dB (C) ; 35~130 dB (F) ; Leq :30-130dB ; LN .: 0-100%
Resolution : 0.1 dB
Accarcy : 1dB
Memory : Maximum value (30groups)
Indicator : Low battery indicator
Alarm : electron
Connector : RS232C
Power supply : 4 x1.5v AAA (UM-4 battery
Size : 236 x 63 x26 mm
Weight : 170g (including batteries)
12. Sound Calibrator
Standard : GB/T 15173, ANSI S1.40 Class2, IEC 942
Output Sound Level : 94 dB, 114 dB
Accuracy : 0.5 dB
Frequency : 1,000 Hz
Design for : 1"" , ½""
Power Supply : 1 x 9V 6F22 Battery
Dimension : 142 x 47 x 47 mm
Weight : 275 gr
13. Anemometer
Measurement units:
1. Air Velocity: M/s, km/h, ft/min, knots
2. Air Flow: CMM, CFM
3. Beaufort Scale: Force
4. Wave Height: M
5. Direction: ° From the North direction
6. Temperature: º C or º F
- Data hold: Maximum value
- Sampling rate: Reading per second approx.
- Air velocity / flow sensor: 3-cup probe
- Automatic power off: 0 - 9 minutes set by users
- Power Supply: 4 x 1.5 AAA size Batteries (included)
- Item weight: ± 260g
- Dimensions main unit: 156 x 67 x 28 mm
- Dimensions Velocity sensor: 65x65x115 mm
- Dimensions of Direction sensor: 86 x 69 x 115 mm
Air Velocity : 0.4-45.0 m/s ; ± (2% + 0.1m/s)
CMM (cubic meters/min): 0 - 9999 m3/min;
CFM (cubic ft/min): 0 ~ 9999 ft3/min
Beaufort scale: 0 ~12
Direction: 0 ~ 360°
Wave Height: 0~14
Air Temperature: 0º C - 60º C/ 32 º F ~ 140 º F
Resolution: 0.1
14. Infrared Thermometer ST530
Temp. Range: ST530: -32 to 530 ºC (26 to 986 ºF)
Accuracy: ± 2%+2 ºC
Resolution: 0.1 ºC/ºF
Field Of View: 12: 1
Emissivity: 0.95
Laser Sighting: Single Point
Laser Output: <1mW, Laser Class II
15. Infrared Thermometer AR872
Temperature Range : -50ºC to 1,250ºC
Accuracy : ±2% or ± 2ºC
Distance Spot Ratio : 30 : 1
Distance Spot Ratio : 30 : 1
Resolution : 0.1ºC for < 1,000ºC
Resolution : 1ºC for > 1,000ºC
Response time & Wavelength : 500ms & (8-14)µm
Repeatability : ±1% or ±1ºC
Average & Difference Function : Yes
Max & Min Function : Yes
ºC / ºF Selection : Yes
Data Hold Function : Yes
Laser Target Pointer Selection : Yes
Backlight Display Function : Yes
Low Battery Indication : Yes
RS-232 / USB Input Interface : No
Corresponding Analyzing Software : No
Power : Alkaline 9Volt
Weight (Approx) : 480 gr
Size : 200x155x59mm
16. Vibration Meter VM6360
Measure :
Acceleration: 20.1 ~ 400 m/s²
Velocity: 0.1 ~ 400 m/s
Displacement: 0.001 ~ 4.0 mm
RPM revolution: 5 to 100,000 r/min
Frequency: 0.1 to 10 kHz
Accuracy: < 5% + 2
Battery: 9 Volt
Size: H185 x W68 x D30mm
Weight: ±230gr
17. Human Vibration Meter
Frequency weightings and measurements for Hand-Arm and Whole Body Vibration
Conforms to ISO Standards 2631 and 5349
Simultaneous 3-channel Measurements: X, Y and Z axes, plus Sum (S)
Lightweight and Portable - operates from two AA batteries or AC power supply
Records up to 200 hours of measurement time history
Programmable AC or DC Signal output
USB and Serial Interface to PC (115.2 kBaud)
18. High Volume Air Sampler
TFIA Series High Volume Air Samplers
Staplex® Model TFIA series High Volume Air Samplers
Indoor or outdoor sampling of airborne particulates
0-70 cubic feet per minute (cfm) [0-2 cubic meters per minute (cmm)] flow range
Spot or continuous monitoring
Portable and lightweight
Built-in rotometer for instantaneous flow reading
Includes 4"" (10.16 cm) diameter filter holder assembly
For use in normal, non-explosive atmospheres
19. Filter Paper
Origin: United States
100 filters TFA No.41
Filter Paper 4"" dia
20. HVAS
Alat untuk mengambil sampel debu di udara
Motor Pump : 3 stage centrifugal blower
Housing : Anodized alumunium
Cal. Flow Range : 10 - 50 CFM
Power : 230 VAC, 50/60 Hz
Holder Filter : 8"" x 10"" (Included)
Filter Paper : 100 sheet (8"" x 10"")
21. Opacity Meter
Untuk pemantauankepekatan asap yang keluar dari cerobong asap
Specification :
- Magnification ratio : 10 x
- Measuring distance : 10 ~ 1000m
- Measuring image diameter : 70mm
- Blackness levels : 0 ~ 5
0 Grade : 0%
1 Grade : 20%
2 Gade : 40%
3 Grade : 60%
4 Grade : 80%
5 Grade : 100%
- Digital camera for select : Olympus Zoom ( 4 megapixel)
- Manual Books
- Tripod
- Carrying Case
22. Analytical Balance
Timbangan analitik digital
Fujitsu FS AR
Capacity: 210g
Readability: 0,1 mg
Repeatability: ±0,1 mg
Linearity: ±0,2 mg
Pan size: 80 mm
Work temp: 25°C ±2.5°C
Built in under hook
23. Meja Timbang
Meja Timbang Tahan Getar
Dimensi : 1200 x 750 x 90 mm
Rangka : Multiplex dilapis HPL
Meja : Granit tebal 50 mm (hitam)
Size : 40 x 60 mm
24. Drying Oven
Electrical requirements: 220V 50Hz
Temperature range: 10~250ºC
Temperature control: ±0.1ºC
Temperature stability: ±0.5ºC
Timing Range: 1~9999min
W*D*H interior (mm): 300*300*270 (24 liter)
W*D*H interior (mm): 420*350*350 (51 liter)
W*D*H interior (mm): 550*350*550 (105 liter)
W*D*H interior (mm): 600*550*600 (198 liter)
25. Water Bath
Penangas Air
Input Power : 1000 W
Electrical requirements: 220V 50Hz
Temperature range: 5~99ºC
Temperature stability: 0.5ºC
Timing Range: 1~9999min
Double column and 2 holes
Interior (mm): 360*200*150, 500watt, (10 Liter)
Double column and 4 holes
Interior (mm): 360*340*150, 1000Watt (18 Liter)
Double column and 6 holes
Interior (mm): 500*340*150, 1500Watt (25 Liter)
Double column and 8 holes
Interior (mm): 700*340*150, 1500Watt (35 Liter)
26. Drying Oven / Incubator
Electrical requirements: 220V 50Hz
Temperature range: 5~65ºC
Temperature control: 0.1ºC
Ambient temperature: 5~35ºC
Temperature stability: 0.5ºC
Shelves per chamber: 2 pcs
Timing Range 1~9999 min
W*D*H interior dimension (mm): 320*300*315 (30 Liter)
W*D*H interior dimension (mm): 350*350*410 (50 Liter)
W*D*H interior dimension (mm): 400*400*500 (80 liter)
27. EPAM 5000
Fungsi: untuk monitoring debu TSP, PM10, PM2,5 & PM1.0µM
Display : Large Alphanumeric LCD-4 line, 20 character display
Operation : Four key splash proof membrane switch - menu driven
Calibration : Gravimetric reference NIST traceable - SAE fine test dust
Accuracy : ± 10% to filter gravimetric SAE fine test dust
Sensing range : 0.001-20.0 mg/m³ or .01 - 200.0 mg/m³ (opt)
Particulate size range : 0.01 - 100 µm
Precision : ± .003 mg/m³ (3 µg/m³)
Sampling flow rate : 1.0 - 5.0 liters/minute
Filter cassette : 47mm FRM style; Alarm output : 90db at 3 ft
Recording time : 1 second to 15 months
Sampling rate : 1 sec, 10 sec, 1 min, and 30 min
Data storage : 21, 600 data points
Memory & time storage : >5 years
Real-time clock & display : Hours, Min, Sec, Day, Month, Year
Data display : Concentration range in mg/m³ & TWA, MAX, MIN, STEL, Date, Time; Digital output : RS-232
Temperature : Operation: -10°C to 50°C; Storage: -20°C to 70°C
Power : Rechargeable and interchangeable battery
Operating time : >24 hours on battery
Charging time: Approx 22 hours; Humidity : 95% non-condensing; Dimensions (case) : 14.0"" x 6.0"" x 10.0""
Weight : 12 lbs.
28. Low Volume Sampler
Portable, lightweight Low Volume Air Samplers highly effective for accurate samples from immediate vicinity of sampler for air pollutants; asbestos fibers; radioactive particles; industrial, governmental, hospital; mine air hazards; etc. Suitable for mobile or fixed position operation in normal non-explosive atmospheres.
Flow Control :
Fully adjustable flow control valve on direct-reading rotometer, settable over the full flow range. Accurate to ± 5% full scale.
Specifications
Model LV-2
Flow rate 15-35 L/ min.
Dimension / Weight 4 "" x 4 "" x 7 "" / 2.7 kg
Power supply 220-240 Volts AC, 50-60 Hz
29. Impinger
Kapasitas Hisap : Maksimal 1.5 Liter Udara / Menit (lpm)
Teknologi Hisap : Elektromotor-vibrasi katup ganda
Jumlah Pompa Hisap : 5 unit (Independen)
Pengatur Hisapan : Speed Flow Control and Double variable Potensiometer (Independent)
Penunjuk Aliran Udara : Diret reading Flowmeter 1.5 l/min (max)
Lubang/Ukuran : 5 buah,1/4""
Catu daya : AC 220V,50Hz,100VA
DC Charging Baterry Nicad 4x1.2 V
Emergency Power source : 4 x 1.5V UM 1 Battery
Dimensi Mekanikal : 45 x 24x 24 (pxlxt) cm
Perlengkapan Utama : 5 buah tabung impinger
5 buah tabung gelas pengaman
1 lot selang flesibel (1/4"")
Kemampuan Operasi :
Endurance test AC : 24 jam
Endurance test DC : max.5 jam
Material : Plat alumunium 2 mm
Termasuk tripod
30. Combustion Analyzer
O2 : 0 - 21 %
CO2 : 0 - 20,00 %
CO : 0 - 4000 ppm
Temp. : + 5 - + 45 °C
Battery : > 15 h
Inlet-Temperature : 0-100 °C
Size : 74x145x35 mm
9. Model AWA 6291 Real Time Signal Analyzer
Frequency Response:10 Hz~20 kHz±0.2 dB, 1 Hz~23 kHz(±1.0 dB)
Frequency Weighting: A, C, F(Flat)
Time Weighting: F, S, and linear average
Measuring Upper Limit: 130 dB(A),(re. 20 μPa)
Self-generated Noise: <18 dB(A), 23 dB(C), 28 dB(Z)
Measurement of Peak C sound level: 50~143 dB
Linearity Range: 90dB
Sampling Frequency48 kHz
A/D bits: 24 bits
Integrating Time: Manual, 10s, 1min, 10min, 15min,20min, 1h, 4h, 8h, 24h
Anti-aliasing Filter: Cutoff frequency is 23.5 kHz and stopband attenuation is 100 dB
10. Noise Dosimeter
Items : ASV5910
Fulfils Standards : IEC61672 Class 2,IEC61252
Microphone : 1/4”Prepolarized Condenser Mic. including the preamplifier sensitivity about-50 dB
Channel : 2
Frequency Range : Parallel (simultaneous) A, C, Z
Time Weighting : Parallel (simultaneous) F, S, I, peak
Measurement Range of Sound Exposure : 0.01Pa2h~99.99Pa2h
Noise Dose Measurement Range : 0%~9999%
Frequency Range : 20Hz-12.5kHz
The Sound Pressure Level Measurement Range : 60-140dBA,65-140dBC,70-140dBZ(sensitivity: -50 dB ) ; 40-120dBA,45-120dBC,50-120dBZ( sensitivity: -30 dB )
Self-generated Noise : <30dBA
Peak C Sound Level Measuring Range : 80-143dB
Display : 128×64
Outputs : Mini USB interface, no need for driver, or the USB Flash disk
Integrating Function : YES
Measure Parameters : LXYp, LXeq,T, LXYmax, LXYmin, LN, SEL, Lex8h, LAVG, TWA, DOSE, SD, Lpeak
Note: X is A, C, Z; Y is F, S, I; N can be 1-99"
"Statistical Analysis Function : YES
Integral Time : 1s~24h
Data Storage : 2GB Flash RAM , maximum 8187 groups
Download to PC : YES
Recording Precision : 32kHz/16bit,16kHz/16bit,8kHz/8bit optional and 48kHz/16bit, 24kHz/16bit,12kHz/8bit ( user order)
Overrun Instructions : YES
Working Temperature : 0°C~40°C
Dimensions : 68(H)×48(W)×20(D)
Weight : 100g
11. Sound Level Meter
Display: 10mm (0.4″) LCD (Liquid Crystal Display)
Function: LP , Leq ,LN.
Frequency range : 31.5Hz - 8kHz
Measurement range : LP:30 - 130dB (A) ; 35 - 130dB (C) ; 35~130 dB (F) ; Leq :30-130dB ; LN .: 0-100%
Resolution : 0.1 dB
Accarcy : 1dB
Memory : Maximum value (30groups)
Indicator : Low battery indicator
Alarm : electron
Connector : RS232C
Power supply : 4 x1.5v AAA (UM-4 battery
Size : 236 x 63 x26 mm
Weight : 170g (including batteries)
12. Sound Calibrator
Standard : GB/T 15173, ANSI S1.40 Class2, IEC 942
Output Sound Level : 94 dB, 114 dB
Accuracy : 0.5 dB
Frequency : 1,000 Hz
Design for : 1"" , ½""
Power Supply : 1 x 9V 6F22 Battery
Dimension : 142 x 47 x 47 mm
Weight : 275 gr
13. Anemometer
Measurement units:
1. Air Velocity: M/s, km/h, ft/min, knots
2. Air Flow: CMM, CFM
3. Beaufort Scale: Force
4. Wave Height: M
5. Direction: ° From the North direction
6. Temperature: º C or º F
- Data hold: Maximum value
- Sampling rate: Reading per second approx.
- Air velocity / flow sensor: 3-cup probe
- Automatic power off: 0 - 9 minutes set by users
- Power Supply: 4 x 1.5 AAA size Batteries (included)
- Item weight: ± 260g
- Dimensions main unit: 156 x 67 x 28 mm
- Dimensions Velocity sensor: 65x65x115 mm
- Dimensions of Direction sensor: 86 x 69 x 115 mm
Air Velocity : 0.4-45.0 m/s ; ± (2% + 0.1m/s)
CMM (cubic meters/min): 0 - 9999 m3/min;
CFM (cubic ft/min): 0 ~ 9999 ft3/min
Beaufort scale: 0 ~12
Direction: 0 ~ 360°
Wave Height: 0~14
Air Temperature: 0º C - 60º C/ 32 º F ~ 140 º F
Resolution: 0.1
14. Infrared Thermometer ST530
Temp. Range: ST530: -32 to 530 ºC (26 to 986 ºF)
Accuracy: ± 2%+2 ºC
Resolution: 0.1 ºC/ºF
Field Of View: 12: 1
Emissivity: 0.95
Laser Sighting: Single Point
Laser Output: <1mW, Laser Class II
15. Infrared Thermometer AR872
Temperature Range : -50ºC to 1,250ºC
Accuracy : ±2% or ± 2ºC
Distance Spot Ratio : 30 : 1
Distance Spot Ratio : 30 : 1
Resolution : 0.1ºC for < 1,000ºC
Resolution : 1ºC for > 1,000ºC
Response time & Wavelength : 500ms & (8-14)µm
Repeatability : ±1% or ±1ºC
Average & Difference Function : Yes
Max & Min Function : Yes
ºC / ºF Selection : Yes
Data Hold Function : Yes
Laser Target Pointer Selection : Yes
Backlight Display Function : Yes
Low Battery Indication : Yes
RS-232 / USB Input Interface : No
Corresponding Analyzing Software : No
Power : Alkaline 9Volt
Weight (Approx) : 480 gr
Size : 200x155x59mm
16. Vibration Meter VM6360
Measure :
Acceleration: 20.1 ~ 400 m/s²
Velocity: 0.1 ~ 400 m/s
Displacement: 0.001 ~ 4.0 mm
RPM revolution: 5 to 100,000 r/min
Frequency: 0.1 to 10 kHz
Accuracy: < 5% + 2
Battery: 9 Volt
Size: H185 x W68 x D30mm
Weight: ±230gr
17. Human Vibration Meter
Frequency weightings and measurements for Hand-Arm and Whole Body Vibration
Conforms to ISO Standards 2631 and 5349
Simultaneous 3-channel Measurements: X, Y and Z axes, plus Sum (S)
Lightweight and Portable - operates from two AA batteries or AC power supply
Records up to 200 hours of measurement time history
Programmable AC or DC Signal output
USB and Serial Interface to PC (115.2 kBaud)
18. High Volume Air Sampler
TFIA Series High Volume Air Samplers
Staplex® Model TFIA series High Volume Air Samplers
Indoor or outdoor sampling of airborne particulates
0-70 cubic feet per minute (cfm) [0-2 cubic meters per minute (cmm)] flow range
Spot or continuous monitoring
Portable and lightweight
Built-in rotometer for instantaneous flow reading
Includes 4"" (10.16 cm) diameter filter holder assembly
For use in normal, non-explosive atmospheres
19. Filter Paper
Origin: United States
100 filters TFA No.41
Filter Paper 4"" dia
20. HVAS
Alat untuk mengambil sampel debu di udara
Motor Pump : 3 stage centrifugal blower
Housing : Anodized alumunium
Cal. Flow Range : 10 - 50 CFM
Power : 230 VAC, 50/60 Hz
Holder Filter : 8"" x 10"" (Included)
Filter Paper : 100 sheet (8"" x 10"")
21. Opacity Meter
Untuk pemantauankepekatan asap yang keluar dari cerobong asap
Specification :
- Magnification ratio : 10 x
- Measuring distance : 10 ~ 1000m
- Measuring image diameter : 70mm
- Blackness levels : 0 ~ 5
0 Grade : 0%
1 Grade : 20%
2 Gade : 40%
3 Grade : 60%
4 Grade : 80%
5 Grade : 100%
- Digital camera for select : Olympus Zoom ( 4 megapixel)
- Manual Books
- Tripod
- Carrying Case
22. Analytical Balance
Timbangan analitik digital
Fujitsu FS AR
Capacity: 210g
Readability: 0,1 mg
Repeatability: ±0,1 mg
Linearity: ±0,2 mg
Pan size: 80 mm
Work temp: 25°C ±2.5°C
Built in under hook
23. Meja Timbang
Meja Timbang Tahan Getar
Dimensi : 1200 x 750 x 90 mm
Rangka : Multiplex dilapis HPL
Meja : Granit tebal 50 mm (hitam)
Size : 40 x 60 mm
24. Drying Oven
Electrical requirements: 220V 50Hz
Temperature range: 10~250ºC
Temperature control: ±0.1ºC
Temperature stability: ±0.5ºC
Timing Range: 1~9999min
W*D*H interior (mm): 300*300*270 (24 liter)
W*D*H interior (mm): 420*350*350 (51 liter)
W*D*H interior (mm): 550*350*550 (105 liter)
W*D*H interior (mm): 600*550*600 (198 liter)
25. Water Bath
Penangas Air
Input Power : 1000 W
Electrical requirements: 220V 50Hz
Temperature range: 5~99ºC
Temperature stability: 0.5ºC
Timing Range: 1~9999min
Double column and 2 holes
Interior (mm): 360*200*150, 500watt, (10 Liter)
Double column and 4 holes
Interior (mm): 360*340*150, 1000Watt (18 Liter)
Double column and 6 holes
Interior (mm): 500*340*150, 1500Watt (25 Liter)
Double column and 8 holes
Interior (mm): 700*340*150, 1500Watt (35 Liter)
26. Drying Oven / Incubator
Electrical requirements: 220V 50Hz
Temperature range: 5~65ºC
Temperature control: 0.1ºC
Ambient temperature: 5~35ºC
Temperature stability: 0.5ºC
Shelves per chamber: 2 pcs
Timing Range 1~9999 min
W*D*H interior dimension (mm): 320*300*315 (30 Liter)
W*D*H interior dimension (mm): 350*350*410 (50 Liter)
W*D*H interior dimension (mm): 400*400*500 (80 liter)
27. EPAM 5000
Fungsi: untuk monitoring debu TSP, PM10, PM2,5 & PM1.0µM
Display : Large Alphanumeric LCD-4 line, 20 character display
Operation : Four key splash proof membrane switch - menu driven
Calibration : Gravimetric reference NIST traceable - SAE fine test dust
Accuracy : ± 10% to filter gravimetric SAE fine test dust
Sensing range : 0.001-20.0 mg/m³ or .01 - 200.0 mg/m³ (opt)
Particulate size range : 0.01 - 100 µm
Precision : ± .003 mg/m³ (3 µg/m³)
Sampling flow rate : 1.0 - 5.0 liters/minute
Filter cassette : 47mm FRM style; Alarm output : 90db at 3 ft
Recording time : 1 second to 15 months
Sampling rate : 1 sec, 10 sec, 1 min, and 30 min
Data storage : 21, 600 data points
Memory & time storage : >5 years
Real-time clock & display : Hours, Min, Sec, Day, Month, Year
Data display : Concentration range in mg/m³ & TWA, MAX, MIN, STEL, Date, Time; Digital output : RS-232
Temperature : Operation: -10°C to 50°C; Storage: -20°C to 70°C
Power : Rechargeable and interchangeable battery
Operating time : >24 hours on battery
Charging time: Approx 22 hours; Humidity : 95% non-condensing; Dimensions (case) : 14.0"" x 6.0"" x 10.0""
Weight : 12 lbs.
28. Low Volume Sampler
Portable, lightweight Low Volume Air Samplers highly effective for accurate samples from immediate vicinity of sampler for air pollutants; asbestos fibers; radioactive particles; industrial, governmental, hospital; mine air hazards; etc. Suitable for mobile or fixed position operation in normal non-explosive atmospheres.
Flow Control :
Fully adjustable flow control valve on direct-reading rotometer, settable over the full flow range. Accurate to ± 5% full scale.
Specifications
Model LV-2
Flow rate 15-35 L/ min.
Dimension / Weight 4 "" x 4 "" x 7 "" / 2.7 kg
Power supply 220-240 Volts AC, 50-60 Hz
29. Impinger
Kapasitas Hisap : Maksimal 1.5 Liter Udara / Menit (lpm)
Teknologi Hisap : Elektromotor-vibrasi katup ganda
Jumlah Pompa Hisap : 5 unit (Independen)
Pengatur Hisapan : Speed Flow Control and Double variable Potensiometer (Independent)
Penunjuk Aliran Udara : Diret reading Flowmeter 1.5 l/min (max)
Lubang/Ukuran : 5 buah,1/4""
Catu daya : AC 220V,50Hz,100VA
DC Charging Baterry Nicad 4x1.2 V
Emergency Power source : 4 x 1.5V UM 1 Battery
Dimensi Mekanikal : 45 x 24x 24 (pxlxt) cm
Perlengkapan Utama : 5 buah tabung impinger
5 buah tabung gelas pengaman
1 lot selang flesibel (1/4"")
Kemampuan Operasi :
Endurance test AC : 24 jam
Endurance test DC : max.5 jam
Material : Plat alumunium 2 mm
Termasuk tripod
30. Combustion Analyzer
O2 : 0 - 21 %
CO2 : 0 - 20,00 %
CO : 0 - 4000 ppm
Temp. : + 5 - + 45 °C
Battery : > 15 h
Inlet-Temperature : 0-100 °C
Size : 74x145x35 mm
31. Particle Counter
Channels : 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm
Flow Rate : 0.1 cfm (2.83 L/min) controlled by internal pump
Count Modes : Concentration, totalize, audio
Counting Efficiency : 50% @0.3 µm; 100% for particles > 0.45 µm (per JIS B9921:1997)
Zero Count : 1 count/5 minute (JIS B9921:1997)
Coincidence Loss : 5% at 2,000,000 particles per ft3
Relative Humidity : ± 7%, 20% to 90% non-condensing
Temperature : ± 3°C, 10 °C to 40 °C (50 °F to 104 °F)
Data Storage : 5000 sample records (rotating buffer) of date, time, counts, relative humidity, temperature, sample volumes, alarms, label
Alarms : Counts, low battery, sensor fail
Delay Time : 0 to 24 hours
Sample Inlet : Isokinetic probe
Interface : RS-232 and RS-485 via RJ-45
32. Emission Monitoring
NDIR 3-Gases
CO : 0-10.000 / 30.000 ppm
Co2 : 0-3% / 20%
CH4 : 0-10.000 / 30.000 ppm
Flue Gas Temp : up to 650 / 1700 C
Power : 100-240Vac / 12Vdc
Size : 438 x 290 x 152 mm
33. Tracer
Response Time : 1 second
Audible alarm (with on/off switch)
Recovery Time : 2 seconds
Easy to read scale and battery check
5-minute warm-up
Power:four 1.5V ""AA"" batteries
Size: 9"" x 4"" x 2.25""
Weight: 1 lb
Inspire absolute confidence with this advanced instrument for targeting natural gas leaks and cracked heat exchangers.
It senses more than 130 gases, including Carbon Monoxide and Methane in concentrations well below their lower explosive limit or OSHA ceilings - down to as little as one PPM - depending on The specific gas.
The system's sensitivity can be adjusted to high, medium or low ranges.
This unit can also be used as an Electronic Termite Sniffer
Common Gases Detected
Acetone
Ammonia
Butane
Carbon Monoxide
Ethylene Oxide
Hydrogen Sulfide
L.P. Gas
Methane
Naphtha
Propane
Sulfur Dioxide
Toluene
Xylene
34. Gas Detector
Gas Detector for 4 Gases :
- H2S - hydrogen sulfide : 0-100 ppm (1ppm)
- O2 - oxygen : 0-30.0% (0.1%)
- CO - carbon monoxide : 0-500 ppm (1ppm)
- LEL combustibles : 0-100%LEL (1%)
Four alarm levels :
- Instant Low and High Alarm for all gases
- TWA (time weighted average) for H2S, CO;
- STEL (short term exposure limit) for H2S, CO; OL
- CO; OL (over limit alarm)
Delivered ready for use with sensors, lithium polymer battey, stainless steel alligator belt clip, calibration hose/cap and instructions
- Size : 10.7x6x3.6 cm, Weight : ± 160 gram
- Temperature operation : -20 to 58ºC
- Humidity : 0% to 95% RH (Non Condensing)
- Simple one-button operation
- Durable, stainless steel alligator clip
35. Gas Leak Detector
Partial List of Detectable Compounds
Minimum Detectable Concentration
Acetylene 50 ppm
Methyl Chloride 5ppm
Iso-Butane (R600a) 500 ppm
Hydrogen Sulfide 5ppm
Methane 500 ppm
Acetone 50 ppm
Ethane (R170) 500 ppm
Methanol 50 ppm
Propane (R290) 500 ppm
Ammonia (R717) 20 ppm
Ethylene 500 ppm
Gasoline 1ppm
36. Refrigeran 5750A
Halogenated Refrigrants Gas Detectors
LED Leak Size Indicators
Two Sensitivity positions, including our unique ScanMode
Reset Button for instant re-calibration
Detachable probe
High efficiency pump
Detects ALL Halogenated Refrigerants, including R-410A, CFCs : R11, R12, R5000, R503, HCFCs : R22, R123, R124, R502, HFCSs : R134a, R404a, R125, etc.
Constant Power Indication
Ultimate Sensitivity, Less than 0.1 ounces per year (3 gr/yr)
Response time : instantaneus
Warming up time : < 110 Sec, in 25ºC, 60% rH
Continuous operation time : 4 hour
Power Supply : 1.5V “C” Batteries ×2
Dimensions : 210(L) × 80(W) × 50(D)mm
Weight : 560g approx.
37. Kitchen Gas Detector
■ Suitable for home users of cylinder (LPG gas) or pipe Gas
■ Effective in detecting gas Leakage
Specification:
■ Detection Method: Diffusion & Catalytic Combustion
■ Power: AC 220V/60 Hz
■ Appropriate Gas: LPG, LNG
■ Power Consumption: 3W
■ Alarm Concentration: LPG= 0.06 - 0.45% (600ppm - 4500ppm)
LNG= 0.06 - 1.25% (600ppm - 12500ppm)
■ Reset Method: Automated reset
■ Output: DC 12V with alarm
■ Temperature: -20 to +40 deg.C
■ Humidity: 95% RH not exceeding
■ Dimension: W320 x H420 x D170
38. Eye Wash
Laboratory Combination Shower/Eyewash Unit
Shower Head : 10"" ABS Shower head.
Piping : 1-1/4"" Hot dip galvanize piping.
Receptor : 11"" Stainless Stell bowl.
Eyewash Head : Twin-flo anti-surge head(8300)
Dust Cover : Protect head and automaticallyrelease With Water pressure.
Activation : Stay open valve with stainless steel ball and stem.
Sign : Universal emergency sign.
Stream Control : Automatic Pressure Compensation flow control.
Connection : Intel : 1-1/4"" IPS ; Waste : 1-1/4"" IPS